How To Set Up Sensi Thermostat
BUTTONS AND ICONS
The Sensi Smart Thermostat can be operated through Wi-Fi using the Sensi app or it tin be operated at the actual wall unit. Advanced features such equally thermostat settings, scheduling and email alerts are only available through the Sensi app.
1. WI-FI STATUS ICON
Indicates Wi-Fi connection status. When you plow Wireless Off onthe thermostat, this is blank.
ii. BACKLIGHT BUTTON
Illuminates the thermostat for ten seconds
3. Fourth dimension
Displays current time.
4. KEYPAD LOCKOUT ICON
This icon indicates the thermostat is locked out. No changes can be fabricated at the thermostat. (Can only be enabled from the Sensi app).
v. BATTERY ICON
When the bars get low, think to change the 2 AA Alkali metal batteries in the back of the thermostat faceplate.
half dozen. UP Pointer BUTTON
Adjusts the temperature setpoint or thermostat configuration.
seven. CURRENT Ready TEMPERATURE
Current set temperature the thermostat will maintain.
8. MENU BUTTON
Access thermostat configurations. (Run across folio half dozen for more details).
nine. DOWN ARROW BUTTON
Adjusts the temperature set indicate or thermostat configuration.
ten. CURRENT ROOM TEMPERATURE
The room temperature at the thermostat.
11. SCHEDULE Push button
Toggles the schedule On or Off. (The thermostat runs a program based on time and temperature set points when Schedule is On).
12. FAN BUTTON
Switches fan style from Machine or On. Leave the fan mode on Auto to allow the thermostat to control the fan as necessary.
13. MODE BUTTON
Switches arrangement mode betwixt Rut, Absurd, Off or Aux. (Machine Mode is only available using the Sensi app).
Basic FUNCTIONALITY
Switching System Manner
Press the "Manner" button to switch between all available organization mode settings. When the Mode is "Off" the thermostat volition not bring on your heating or cooling systems.
Fan Style
If you want to broadcast the indoor blower, you can switch Fan to "On." Turn the Fan dorsum to "Auto" when you want the thermostat to command your indoor blower as necessary. Leaving the Fan in "On" will run your blower continuously.
Property I Temperature
If you want to hold one temperature, plough Schedule "Off." And so, adjust the setpoint using the up and down pointer buttons. The thermostat will hold this temperature, in the fix Mode, until you plow Schedule back "On" or until you lot adjust the set point once more using the up and down arrow buttons.
Temporary Hold
When your schedule is set to "On," your Sensi thermostat controls your home based on the fourth dimension and temperature settings in the current schedule. To temporarily alter your temperature use the upwardly and down arrows in the app or on the thermostat. Your Sensi thermostat will brandish "Temporarily Set To" on the thermostat and will hold your new temperature until the side by side scheduled fix betoken with a minimum agree time of two hours.
Circulating Fan
If yous want to circulate the air in your dwelling house using your indoor blower fan, you can set \this feature in the app or at the thermostat. A percent is selected to dictate how often the fan should run each hour, You tin set 5% increments from x% – 100%.
Instance: If you set the Circulating Fan to 50%, the fan will un 30 minutes every hour. If any heat/cool cycles occur during the hour, their runtime is subtracted from the overall fan run time.
Setting the feature from the thermostat:
i. Press "Menu"
2. Press "Next" until you come to "Fn Setup".
3. Utilise the up arrow button to toggle the percentage you'd like the fan to run each hour.
4. Press "Exit"
Turn Wi-Fi Off
If connecting to Wi-Fi is not an option, you can turn off Wi-Fi on the thermostat and manually ready a time and a schedule from the wall unit. To plow off Wi-Fi:
one. Press "Menu".
ii. Press "Next" until you see "Wireless (Setup)" at the acme of the screen. "On" should exist flashing at the superlative.
3. Utilise the upwardly or down arrow button to change information technology to "Off".
4. Printing "Exit".
Transmission SETTINGS
Setting the Time Manually
When connecting the thermostat to Wi-Fi, the time will sync automatically. If non connecting to Wi-Fi, follow these steps to set the time at the thermostat.
1. Turn Wi-Fi Off. (Refer to department "Turn Wi-Fi Off" on page 4).
2. Press and hold the "Schedule" button.
3. The screen will get bare and the time volition start flashing at the meridian. Use the upward and down arrow buttons to rotate through the times until you get to the appropriate time of twenty-four hour period.
iv. Press "Exit".
Setting a Schedule
When connecting the thermostat to Wi-Fi, the schedule is programmed based on fourth dimension and temperature set points from the Sensi app. If yous are non connecting to Wi-Fi, follow these steps to set a basic vii twenty-four hours schedule with 4 mandatory fix points. (More robust scheduling options are just available through the Sensi app.)
1. Turn Wi-Fi Off. (Refer to section "Turn Wi-Fi Off" on folio four).
2. Use the "Mode" push to set which type of schedule it will be: Heat or Absurd.
iii. Press and hold the "Schedule" button, until y'all run into the fourth dimension flash at the top of the screen
a. Suit the time on the thermostat if needed, using the up and down arrow buttons.
4. Press "Next"
5. You will come across a big number in the center of the screen. This refers to your set point.
a. The time will be flashing at the top of the screen. Conform the fourth dimension of the first setpoint using the up and down arrow buttons.
b. Press "Side by side". The setpoint will be flashing. Accommodate the setpoint using the up and down arrow buttons.
c. Press "Next".
d. Echo steps a-c for the 2nd, 3rd and 4th set points.
6. Press "Get out".
7. Make sure "Schedule" is set up to "On" on the thermostat.
Case Schedule
If you need to keep rails of your time and temperature ready points, utilize this table.
SAMPLE SCHEDULE
PERIOD | DAILY START TIME | DAILY TEMP | |
Heat | 1st | 6:00 am | seventy° F |
twond | 8:00 am | 62° F | |
3rd | 5:00 pm | 70° F | |
4th | 10:00 pm | 62° F | |
Cool | onest | 6:00 am | 78° F |
iind | eight:00 am | 85° F | |
iiird | v:00 pm | 78° F | |
4th | 10:00 pm | 82° F |
COMPLETE YOUR SCHEDULE
Menstruum | DAILY START Fourth dimension | DAILY TEMP | |
Heat | 1st | half dozen:00 am | |
iind | viii:00 am | ||
3rd | 5:00 pm | ||
4thursday | 10:00 pm | ||
Cool | anest | 6:00 am | |
2nd | viii:00 am | ||
3rd | 5:00 pm | ||
4th | 10:00 pm |
Pressing "Menu" at the thermostat allows you to change a serial of settings to customize the thermostat for your specific organisation. Refer to the nautical chart below for a complete listing of thermostat configurations and what they stand for. If y'all are installing the thermostat on the wall for the outset time, we highly recommend that yous download the Sensi app and follow the installation instructions.
However, if you are experiencing an issue or you want to check your organisation configurations, you tin manually configure your thermostat too. Acquire more about how to properly configure your thermostat by searching "configure" on our support site at sensi.emerson.com/en-us/support.
Display Code | Menu particular | Default | Options |
Wireless Setup Connects Thermostat to Wi-Fi network | Connect | ||
Fahrenheit or Celsius | F | F c | |
Outdoor Equipment Configuration Cooling or rut pumps | AC2 | AC1 – Conventional Cooling i (Single Stage) AC2– Conventional Cooling two (Two-Stage) HP1 – Heat Pump 1 (Single Stage) HP2– Oestrus Pump two (Two-Phase) AC0– No Cooling | |
Indoor Equipment Configuration For Gas or Electric Heat | EL2 | EL1– Electric 1 (Single Stage) EL2– Electrical 2 (Two-Stage) FAn GA1 Gas 1 (Single Stage) GA2 Gas two (Two-Phase) | |
Reversing Valve Position Selects "O" or "B" Setting For Heat Pumps Only | 0 | O B 2 | |
Fn | Circulating Fan | OFF | Off/10% – 100% (five% increments) |
H AA | Humidification Add Accessory | OFF | Off/On |
H SP | Humidification Set Signal | OFF | Off/5% – 50% (5% increments) |
dH AA | Dehumidification Add Accessory | Od | Od/Oc Od – Optimal dehumidification (Overcool to dehumidify) Oc – Optimal comfort (Wired dehumidification) |
dH SP | Dehumidification SetPoint | OFF | Off/40% – 95% (5% increments) |
Wireless Radio Turns Wi-Fi Radio On/Off | ON | Off/On |
WIRING TERMINALS
See below for definitions of the wiring terminals on the sub-base of the thermostat.
Terminal outputs and wiring diagrams
TERMINAL Characterization | DEFINITION |
RH* | Power for heating, 24V |
RC* | Power for cooling, 24V |
C** | Common wire, 24V |
G | Indoor blower (fan) |
Y | First outdoor stage cooling on conventional systems or first heat and cool on heat pump systems |
Y2/* | 2nd outdoor phase cooling on conventional systems or second oestrus and cool on two stage heat pump systems or humidifier |
Due west/E | Start indoor stage heat on conventional systems or outset stage auxiliary/emergency heat on estrus pump systems |
W2/* | 2d indoor stage heat on conventional systems or 2nd stage auxiliary/ emergency heat on heat pump systems or dehumidifier |
O/B | Changeover (reverse valve) connectedness for heat pump or zone panel systems |
L | Rut Pump system, "L" wire connection |
* If the one-time thermostat has split up RC and RH wires coming out of the wall, clip the RC/ RH jumper on the back of the thermostat above the battery compartment.
**The mutual wire could be labeled "C" on your old thermostat, or information technology could be labeled "B"
or "X." Please refer to the owner'due south manual of your old thermostat for description.
Does Wire Color Correspond to the Thermostat Terminals?
Wire color does non always correspond to the thermostat letters. A white wire may be attached to the "W" terminal on the old thermostat, or it may be attached to a different terminal with a dissimilar letter. Be certain to take a photograph of the sometime thermostat that shows the wire colors and terminal messages before labeling and removing whatever wires.
Back OF THE FACEPLATE
Below is a picture of the back of the Sensi thermostat faceplate. The backplate shows the jumper wires, battery compartment, and some useful information almost your thermostat.
- SENSI SECURITY Lawmaking
Necessary for connecting to Wi-Fi. Also establish on the Welcome Guide in the packaging. - MODEL NUMBER
Illustrates whether you purchased the professional person or the DIY model. - APPLE HOMEKIT Code
The 8 digit code used to add Sensi Thermostat to Apple HomeKit.. - RC/RH INTERNAL JUMPER WIRE
Only clip this if you have separate RC and RH transformers coming out of the wall. - BATTERY COMPARTMENT
Two AA Alkali metal batteries are used for backup purposes. When y'all see the battery indicator bar on the thermostat display reach 3 bars, supervene upon these batteries to maintain Wi-Fi connectivity. - DATE CODE
When your thermostat was manufactured. - MAC ID
Unique number that identifies the thermostat.
Documents / Resources
References
- Sensi Support | Sensi US